Wood uses broadband sensors to measure low-intensity stress waves.

Civil engineering professor Clint Wood traveled to Mexico City and Puebla, Mexico, last week to study the recent earthquake’s impact on buildings and infrastructure. He was chosen to participate in a Geotechnical Extreme Events Reconnaissance, or GEER, mission sponsored by the National Science Foundation.

As a geotechnical earthquake engineer, Wood focuses his research on dynamic soil characterization. He uses broadband seismometers to measure low-intensity stress waves. By measuring the frequency and wavelength of these waves as they pass through arrays of seismometers, he can estimate the shear-wave velocity and layering of the soil underneath the arrays. Understanding the shear-wave velocity of the soil helps engineers understand ground motions recorded during earthquakes and contributes to the design of buildings that can better withstand various stress waves created by earthquakes.

Bridge failures severed lifelines to rural areas.

Below Wood’s account of his experience:

During our final days in Mexico, we traveled to Puebla and some smaller towns farther south, closer to the epicenter. A number of good case histories were observed in these towns, including three 22-story buildings that had structural distress and rocking of the foundations. We made measurements at these structures, so we could estimate the seismic demand on the structures to better evaluate their performance.

Typical failures of unreinforced masonry structures were observed throughout the smaller towns. We also observed several bridge embankment failures that severed lifelines to some smaller areas.

Overall, many deaths from the earthquake were caused by the collapse of structurally deficient buildings, most of which were built before 1985, when a large subduction zone earthquake killed more than 5,000 people in the Mexico City area. Many of these buildings had what structural engineers call “soft story” parking areas, meaning they contained fewer interior walls in the first story to allow for parking. Soft stories are a problem during earthquakes because they have lower shear resistance than upper floors making the first story more vulnerable to collapse. This emphasizes the need for seismic retrofit of buildings considered structurally deficient.

When ground shaking occurs due to an earthquake, buildings want to stay in place due to inertia forces, while the ground moves under the building. This creates tremendous lateral or shear forces on the building. Buildings that have adequate vertical supports to resist gravity loads may lack the necessary shear resistance to address the lateral forces caused by an earthquake. Buildings lacking shear reinforcement or lateral capacity often fail during earthquakes. Some collapse entirely, but in other buildings, the bottom floor – or even a middle floor! – collapse while the rest of the building remains intact.

Wood observed buildings that had one floor collapse while all other levels remained intact.

This may sound odd, but, destructive as this earthquake was, it could have been worse. Rather than a subduction zone earthquake, similar to the 1985 earthquake where the fault rupture is near the intersection of two tectonic plates, the recent magnitude 7.1 earthquake was what geologists call an intra-plate earthquake, meaning the pressure at the edges of the tectonic plates caused stress and movement within the plate. Subduction zone earthquakes often produce more low-frequency waves that cause greater damage to taller buildings and would have placed a higher seismic demand on many tall structures in Mexico City.